2001 Honda Accord, fan problem
When i am setting the rotating fan button to position 1 and 2 there is
no air coming out of the vents. But works perfectly at position 3 and
4. Now, the question is, couls this be a problem with the rotating
button or a problem with the motor?
Thanks for any help.
no air coming out of the vents. But works perfectly at position 3 and
4. Now, the question is, couls this be a problem with the rotating
button or a problem with the motor?
Thanks for any help.
#2
Guest
Posts: n/a
Re: 2001 Honda Accord, fan problem
I had a Toyota do this years ago. Turned out that the fan speed
switch was selecting different resistors that altered the voltage
to the fan, thus adjusting its speed. The resistors were mounted
in the air flow, presumably to cool them. In any event, the low
speed resistor (the highest value) had burned out. Repair was a
simple replacement of this component.
Since the fan works on 3 & 4, it is unlikely that there is anything
wrong with it.
Dan
Dan (dnbertrand@hotmail.com) writes:
> When i am setting the rotating fan button to position 1 and 2 there is
> no air coming out of the vents. But works perfectly at position 3 and
> 4. Now, the question is, couls this be a problem with the rotating
> button or a problem with the motor?
>
> Thanks for any help.
switch was selecting different resistors that altered the voltage
to the fan, thus adjusting its speed. The resistors were mounted
in the air flow, presumably to cool them. In any event, the low
speed resistor (the highest value) had burned out. Repair was a
simple replacement of this component.
Since the fan works on 3 & 4, it is unlikely that there is anything
wrong with it.
Dan
Dan (dnbertrand@hotmail.com) writes:
> When i am setting the rotating fan button to position 1 and 2 there is
> no air coming out of the vents. But works perfectly at position 3 and
> 4. Now, the question is, couls this be a problem with the rotating
> button or a problem with the motor?
>
> Thanks for any help.
#3
Guest
Posts: n/a
Re: 2001 Honda Accord, fan problem
In article <172397cb.0405180359.dbbd725@posting.google.com> ,
dnbertrand@hotmail.com (Dan) wrote:
> When i am setting the rotating fan button to position 1 and 2 there is
> no air coming out of the vents. But works perfectly at position 3 and
> 4. Now, the question is, couls this be a problem with the rotating
> button or a problem with the motor?
>
> Thanks for any help.
It's a problem with the "rotating button".
--
NEWSGROUP SUBSCRIPERS MOTTO
We respect those subscribers that ask for advice or provide advice.
We do NOT respect the subscribers that enjoy criticizing people.
dnbertrand@hotmail.com (Dan) wrote:
> When i am setting the rotating fan button to position 1 and 2 there is
> no air coming out of the vents. But works perfectly at position 3 and
> 4. Now, the question is, couls this be a problem with the rotating
> button or a problem with the motor?
>
> Thanks for any help.
It's a problem with the "rotating button".
--
NEWSGROUP SUBSCRIPERS MOTTO
We respect those subscribers that ask for advice or provide advice.
We do NOT respect the subscribers that enjoy criticizing people.
#4
Guest
Posts: n/a
Re: 2001 Honda Accord, fan problem
"Dan" <dnbertrand@hotmail.com> wrote in message
news:172397cb.0405180359.dbbd725@posting.google.co m...
> When i am setting the rotating fan button to position 1 and 2 there is
> no air coming out of the vents. But works perfectly at position 3 and
> 4. Now, the question is, couls this be a problem with the rotating
> button or a problem with the motor?
>
> Thanks for any help.
Definitely a blower resistor, should run about $35.00 US at a dealer